Turn your parking into a charging destination that earns
Offer EV charging to your customers, guests, tenants and employees, and earn extra revenue from space you already own. Rudved EV designs, supplies and supports the chargers, the software and the driver app.
The Right Charger Depends on How Long Drivers Stay
A hotel guest parks overnight. A highway driver stops for twenty minutes. Match the charger to the dwell time and your charging revenue and customer experience both improve.
Hotels, resorts & cafés
How Drivers Park
Hours to overnight; guests value convenience
Suggested Rudved Setup
Air 5 AC (7 kW or 11 kW); a 60 kW DC for highway stopovers
Malls & retail centres
How Drivers Park
One to three hours of shopping
Suggested Rudved Setup
Air 5 AC (22 kW) with a Doer DC 60 kW for quick top-ups
Offices & corporate campuses
How Drivers Park
Full working day; employees, visitors and company fleet
Suggested Rudved Setup
Air 5 AC (7 kW, 11 kW or 22 kW)
Housing societies & developers
How Drivers Park
Overnight at home; resident-led demand
Suggested Rudved Setup
Air 1 or Air 5 AC (7 kW); Air 5 (11 kW) for shared bays
Petrol pumps & highway retail
How Drivers Park
Short stops; drivers want speed
Suggested Rudved Setup
Doer DC 60 kW, 120 kW or 240 kW
Parking operators & commercial real estate
How Drivers Park
Mixed: short stays and monthly parkers
Suggested Rudved Setup
AC bays plus one or more Doer DC chargers
Charger Models
AC for Long Stays, DC for Fast Turnaround
Start with AC where vehicles stay parked for hours, and add DC where drivers want to charge and go. Our chargers use Type 2 on AC and CCS2 on DC.
Air 1 (7 kW) Cable Version
Type 2 AC, tethered cable, 7.4 kW
IP65 rated, OCPP 1.6J
Best for
Housing society bays, small parking lots and cafés
Air 5 (7 kW, 11 kW and 22 kW) Cable Version
Single and 3-phase AC, Type 2, IP65
11 kW for faster 3-phase charging at offices; 22 kW for high-speed AC in commercial parking
Best for
Hotels, malls, office campuses and commercial parking
Doer DC 60 kW (Dual Gun)
CCS2 dual gun, two vehicles charging at once
Modular 2×30 kW design; 200 V to 1000 V output, 0 to 200 A
Ethernet or 4G, remote start/stop and remote software upgrade; IP54 outdoor rating
2-year warranty and 7×24 service line
Best for
Fuel retail, malls, highway hospitality and busy public bays
Doer DC 120 kW and 240 kW (Dual Gun)
CCS2 dual gun with OCPP 1.6J
Higher power for faster turnaround at high-footfall sites
Best for
Highway forecourts and large commercial hubs
Site Planning
A Working Charging Station Is a System
The charger is one part of the project. Planning from the grid connection to the driver’s phone avoids surprises at installation.
Power
Sanctioned load or load enhancement, panel readiness, transformer capacity if needed, protection devices and earthing.
Chargers
The right AC and DC mix for your parking behaviour, with cable length and bay layout planned together.
Site Work
Foundation, cable routing, bay marking, bollards, canopy, signage and lighting.
Software
Remote monitoring, fault alerts and session records through an OCPP-based charger management system.
Driver Experience
Drivers find your chargers, check slot availability and start charging from the Rudved EV app.
Support
24/7 customer support so a fault doesn’t become a bad review for your property.
Rudved’s team reviews your site power and layout before you commit, so the quote reflects the real installation scope.
Ownership Options
Choose How You Want to Run It
Charging adds a new revenue line and gives customers a reason to choose your property and stay longer. Choose the model that fits how involved you want to be.
Buy It
Own the charging hardware and run it your way, including pricing and branding. Rudved currently works on a capex model.
Managed Ownership
You fund a Rudved-branded hub and we deploy and run it, while you collect the income.
White-Label
License Rudved’s hardware and software to run charging under your own brand.
Where the Value Comes From
Charging Income
Revenue from every session on your site.
Longer Visits
Drivers charging at a mall, hotel or café tend to spend more time on site.
Tenant & Buyer Appeal
EV-readiness is a selling point for offices, residential projects and hospitality.
Brand Positioning
Show customers your property is built for the electric future.
Software & App
Easy for Drivers, Simple for You to Run
Rudved EV App
Drivers locate your chargers on a map, check live slot availability and start charging in moments. The app is on Google Play and the App Store.
Remote Monitoring
Track charger status, sessions and faults from a dashboard, using OCPP 1.6J.
Smart Charging
Align charging with cost-effective power use and real-time demand.
Access Control
RFID and app-based start options, so you decide who charges on your site.
Payments & Tariff
Set your tariff and collect payment through the app.
24/7 Support
A dedicated support team is available around the clock.
Planning Checklist
Answer These First and Your Quote Gets Faster and Sharper
Questions About Your Site
Who will use the chargers: guests, employees, residents or the public?
How many vehicles a day do you expect?
What is the typical parking time?
Is power already available, or does the site need an upgrade?
How far is the electrical panel from the proposed charging bays?
Decisions to Make
Charger Type
AC, DC or a mix, and the power rating for each.
Gun Configuration
Single or dual gun, and cable length to suit your bays.
Cost depends on the charger mix, number of guns, your site’s available power, installation work and software. Share your site details and we’ll send a quote that covers the full project, not only the charger.
No. Electrical work, installation, civil work, software and support are part of the project. We include them in the proposal so you see the complete picture.
AC suits places where vehicles stay parked for hours, such as hotels, offices and societies. DC suits fuel retail, malls and highway sites where drivers want speed. Many properties use both.